Overview
The L2 fault code on an Ideal Logic/Logic Plus boiler means the boiler attempted to ignite or maintain a flame but the flame was not detected, so the boiler went into an ignition lockout. The boiler’s safety controls shut off the gas to prevent unburned gas from accumulating, so heating and hot water will be unavailable while the fault is present. L2 is a general ignition/flame-failure message and does not point to one single failed part. Causes range from simple, temporary issues you can check yourself (power loss, frozen condensate pipe, closed gas isolation) to component failures that require specialist tools and gas qualifications (faulty flame sensor/probe, failed spark/igniter unit, stuck or faulty gas valve, low gas pressure or blocked flue). Because the fault involves gas and ignition, safety is the priority: some basic checks and a reset are reasonable for a homeowner, but most internal diagnostic and repair work must be done by a Gas Safe registered engineer.
Troubleshooting Steps
Safety precautions:
1) If you smell gas, stop immediately, do not operate electrical switches, open doors and windows, leave the property and call the gas emergency number. Do not attempt repairs.
2) Only perform external, non-invasive checks yourself. Do not open the boiler case or attempt to adjust gas components or ignition parts unless you are a Gas Safe registered engineer.
3) Turn off electrical power to the boiler before touching any external controls or checking isolate switches. Keep naked flames away from the boiler and flue terminals.
Initial checks a homeowner can do:
1) Check boiler display and perform a reset. For older Ideal Logic models move the mode dial to Reset and hold for three seconds or press the reset button on newer units. Wait and see if the boiler attempts to light again. If it restarts and stays running, monitor for recurrence.
2) Confirm mains power and fuses. Check the consumer unit and any fused spur supplying the boiler. Ensure the boiler is powered and the programmer/thermostat is calling for heat.
3) Verify your gas supply: test other gas appliances (hob/oven) to confirm gas is available. Ensure any prepayment meter has credit. Check the emergency control valve (ECV) at the meter and the gas isolation valve under the boiler are fully open (handle parallel to pipe).
4) Inspect the condensate pipe (usually a small white plastic pipe exiting the property near ground level). In cold weather it can freeze and block condensate discharge. If frozen, thaw it as described below.
5) Check the external flue terminal and air intake for obvious blockages (nests, leaves, debris). Do not insert objects into the flue.
Simple homeowner fixes and how to do them safely:
1) Thawing a frozen condensate pipe: pour warm (not boiling) water over the exposed section of pipe, use a warm towel, or a hairdryer on a low setting to slowly melt ice. Do not use open flames or extremely hot water. Once thawed, insulate/lag the pipe and consider routing it more vertically to reduce re-freezing.
2) If reset temporarily clears the fault, try running the boiler and watch for repetitive lockouts. If it reoccurs repeatedly, do not repeatedly reset as this delays proper diagnosis.
3) Clear light obstructions from the flue terminal and keep air vents unobstructed. Replace any trimmed insulation or lagging that was removed during checks.
What requires a Gas Safe engineer (do not attempt yourself):
1) Diagnostics inside the boiler: testing gas inlet pressure with a manometer, measuring spark generator/igniter resistance, testing the flame sensing probe, checking wiring to the PCB, and measuring voltages during ignition attempts. These require specialist tools and gas-safe competence.
2) Component replacement: replacing the flame probe/electrode, igniter unit, gas valve, burner, or PCB must be carried out by a qualified engineer. A stuck or faulty gas valve or failing ignition module are common causes of L2 and need professional attention.
3) Gas meter/regulator problems or persistent low gas pressure should be reported to your gas supplier; an engineer may coordinate with the supplier for meter checks.
When to call a professional and what to tell them:
1) Call a Gas Safe registered engineer if the L2 fault persists after the basic checks above, if thawing the condensate pipe does not solve it, if you suspect a component failure, or if you are uncomfortable performing the checks.
2) When you call, tell the engineer: the boiler model (Ideal Logic / Logic Plus), that L2 is displayed, what checks you have already done (reset, checked power, gas to other appliances, thawed condensate pipe, checked flue), and whether the fault is intermittent or constant.
Final notes:
1) L2 can sometimes be a one-off transient fault and may clear after a reset. Repeated or persistent L2 lockouts indicate an underlying fault that needs proper diagnosis.
2) For safety and legal reasons, any internal gas or ignition work must be done by a Gas Safe registered engineer. Do not attempt to repair or replace ignition electrodes, gas valves, or internal wiring yourself.
Helpful Resources
Ideal Logic L2 / F2 Fault Code | Gas Boiler Breakdown | How To Repair A Gas Boiler
video
Ideal Logic L2 Boiler Fault Code: Causes & Fixes
article
Logic Code Combi ESP1: Experiencing an L2 on your Ideal Logic Code Combi ESP1 boiler
video
How I fixed an L2 Fault Code on an Ideal Logic Boiler in Hull
article
Logic Max System Guide | 15 18 24 & 30kW | Ideal Heating
article
Boiler Manual
Download the official PDF manual for the Ideal Logic Max System / Logic Plus System.